22 October 1999 PN-CCD camera for XMM and ABRIXAS: design of the camera system
Elmar Pfeffermann, Heinrich W. Braeuninger, Edgar Bihler, Ulrich G. Briel, Horst Hippmann, Peter Holl, Josef Kemmer, Eckhard Kendziorra, Guenther Kettenring, Baerbel Kretschmar, Markus Kuster, Norbert Meidinger, Gerd Metzner, Bernhard Pflueger, Claus Reppin, Heike Soltau, Karl-Heinz Stephan, Lothar Strueder, Joachim E. Truemper, Christoph von Zanthier
Author Affiliations +
Abstract
The pn-Charge Coupled Device (pn-CCD) camera was developed as one of the focal plane instruments for the European Photon Imaging Camera on board the x-ray multi mirror mission. An identical camera was foreseen on board ABRIXAS, a German x-ray satellite. The pn-CCD camera is an imaging x- ray detector for single photon counting, operating at a temperature below -80 degrees C. Due to a 0.3 mm depletion depth of the CCDs, the detector has a high quantum efficiency up to 15 keV. The effective area of the instrument is 6 cm X 6 cm with 12 CCDs monolithically integrated on a single silicon wafer. The camera includes a filter wheel with different filters for suppression of optical and UV light. A radioactive source provides an in- orbit calibration. In this paper we give an overview of the mechanical, thermal and electrical design of the instrument and a description of different readout and test modes. More detailed information about the performance and calibration of the instrument can be found in companion papers.
© (1999) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Elmar Pfeffermann, Heinrich W. Braeuninger, Edgar Bihler, Ulrich G. Briel, Horst Hippmann, Peter Holl, Josef Kemmer, Eckhard Kendziorra, Guenther Kettenring, Baerbel Kretschmar, Markus Kuster, Norbert Meidinger, Gerd Metzner, Bernhard Pflueger, Claus Reppin, Heike Soltau, Karl-Heinz Stephan, Lothar Strueder, Joachim E. Truemper, and Christoph von Zanthier "PN-CCD camera for XMM and ABRIXAS: design of the camera system", Proc. SPIE 3765, EUV, X-Ray, and Gamma-Ray Instrumentation for Astronomy X, (22 October 1999); https://doi.org/10.1117/12.366499
Lens.org Logo
CITATIONS
Cited by 5 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Cameras

Charge-coupled devices

X-rays

Semiconducting wafers

Calibration

Imaging systems

RELATED CONTENT

The Hard X ray Imager (HXI) for the ASTRO H...
Proceedings of SPIE (July 31 2014)
PN CCD camera for XMM performance of full frame...
Proceedings of SPIE (October 15 1997)
High speed large format x ray CCDs for ESA's XEUS...
Proceedings of SPIE (January 25 2002)
Status of the calibration of the EPIC pn camera onboard...
Proceedings of SPIE (February 03 2004)

Back to Top