You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
21 July 2000Experimental validation of a thermal model used to predict the image placement error of a scanned EUVL reticle
Lithographic masks must maintain dimensional stability during exposure in a lithographic tool to minimize subsequent overlay errors. In extreme ultraviolet lithography (EUVL), multilayer coatings are deposited on a mask substrate to make the mask surface reflective at EUV wavelengths. About 40% of the incident EUV light is absorbed by the multilayer coating which leads to a temperature rise. The choice of mask substrate material and absorber affects the magnitude of thermal distortion. Finite element modeling has been used to investigate potential mask materials and to explore the efficiency of various thermal management strategies. An experimental program was conducted to validate the thermal models used to predict the performance of EUV reticles. The experiments closely resembled actual conditions expected within the EUV tool. A reticle instrumented with temperature sensors was mounted on a scanning stage with an electrostatic chuck. An actively cooled isolation plate was mounted in front of the reticle for thermal management. Experimental power levels at the reticle corresponding to production throughput levels were utilized in the experiments. Both silicon and low expansion glass reticles were tested. Temperatures were measured a several locations on the reticle and tracked over time as the illuminated reticle was scanned. The experimental results coupled with the predictive modeling capability validates that the assertion that the use of a low expansion glass will satisfy image placement error requirements down to the 30 nm lithographic node.
The alert did not successfully save. Please try again later.
Steven E. Gianoulakis, Marcus J. Craig, Avijit K. Ray-Chaudhuri, "Experimental validation of a thermal model used to predict the image placement error of a scanned EUVL reticle," Proc. SPIE 3997, Emerging Lithographic Technologies IV, (21 July 2000); https://doi.org/10.1117/12.390035