You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
22 September 1983Long Wave Infrared Testing At NBS
At present, National Bureau of Standards (NBS) work in the Long Wave Infrared (LWIR) spectral region is performed using three calibration facilities. These facilities are: 1) a spectral calibration facility for "medium temperature" (350-1300 K) blackbodies, 2) a broadband facility for calibrating blackbodies (-50 - +150°C) against a room temperature background and 3) a facility for calibrating blackbodies (150-600 K) in a cryogenic environment. Two recent calibrations for the LWIR community will be described to illustrate the features and limitations of the present NBS facilities: for the first calibration [in facility (3)] the total radiant output at a source in a small, well-defined solid angle was measured using an electrically calibrated absolute radiometer; for the second [in facility (2)], a source was radiometrically compared with a high-quality, variable temperature blackbody using an IR radiometer with a variable wavelength filter. Future plans to enlarge and upgrade the cryogenic facility to provide increased sensitivity will be described. Systematic studies of the errors due to diffraction, polarization, and attenuation are planned. Future work to explore the possibility of basing calibrations on self-calibration techniques with LWIR detectors will also be described.
C. R. Yokley
"Long Wave Infrared Testing At NBS", Proc. SPIE 0416, Applications of Optical Metrology: Techniques and Measurements II, (22 September 1983); https://doi.org/10.1117/12.935912
The alert did not successfully save. Please try again later.
C. R. Yokley, "Long Wave Infrared Testing At NBS," Proc. SPIE 0416, Applications of Optical Metrology: Techniques and Measurements II, (22 September 1983); https://doi.org/10.1117/12.935912