Paper
9 November 2000 Progression monitoring of the flow front in RTM process using fibre Bragg grating sensors
C. Novo
Author Affiliations +
Proceedings Volume 4185, Fourteenth International Conference on Optical Fiber Sensors; 418545 (2000) https://doi.org/10.1117/12.2302292
Event: Fourteenth International Conference on Optical Fiber Sensors, 2000, Venice, Italy
Abstract
Monitoring and control of RTM process is essential to minimise trial and errors and optimise cycle productions. Hence a research programme was established to study different systems to control the process. In this paper, several experiments are described in which an on-line system based on fibre Bragg sensors was implemented.
© (2000) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
C. Novo "Progression monitoring of the flow front in RTM process using fibre Bragg grating sensors", Proc. SPIE 4185, Fourteenth International Conference on Optical Fiber Sensors, 418545 (9 November 2000); https://doi.org/10.1117/12.2302292
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Fiber Bragg gratings

Composites

Process control

Capillaries

Fiber optics sensors

Protactinium

Back to Top