9 July 2001 Theoretical study of variable function (cutting/coagulating) laser surgical system using continuous-wave 3 μm, 2 μm cascade Ho3+:ZBLAN fiber laser
Author Affiliations +
Abstract
We theoretically investigated variable-function (cutting/coagulating) characteristics of the continuous wave 3 μm, 2 μm cascade Ho3+:ZBLAN fiber laser using 3D heat-conduction calculation with finite element method. We have modified a commercial-available simulator in order to calculate heat conduction and thermal ablation process in soft tissue. In this calculation we considered specific heat rise due to the thermal denaturation of protein and volume shrinkage caused by temperature elevation. Beam profile, beam traveling speed, output power, and absorption coefficient were employed to describe the laser beam. The configuration of cutting groove and temperature distribution were calculated by varying the power ratio of the two wavelengths. Coagulation layer was defined as the region that was over 60°C for 1 second because we found that birefringence loss in porcine myocardium observed by a polarizing microscope occurred on this temperature history. When we increased the power ratio of 2 micrometers radiation to the total power of 0.9 W from 0% to 100% at the traveling speed of 0.5 mm/s, the incision depth decreased form 1.45 mm to 0.25 mm, while the coagulation layer thickness increased from 0.17 mm to 0.70 mm. We experimentally performed laser cutting on the same condition by our calculation using extracted porcine myocardium and compared this experimental results with the calculated results. We demonstrated that the incision depth and coagulation layer thickness estimated by our calculation indicated good agreement with the experimental results within 20% differences regarding the function variability by 3 μm/2 μm light mixing.
© (2001) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Kyota Naruse, Tsunenori Arai, Satoko Kawauchi, Tetsumi Sumiyoshi, Shoichi Kiyoshima, Miya Ishihara, Shunichi Sato, Makoto Kikuchi, Hitoshi Sekita, and Minoru Obara "Theoretical study of variable function (cutting/coagulating) laser surgical system using continuous-wave 3 μm, 2 μm cascade Ho3+:ZBLAN fiber laser", Proc. SPIE 4257, Laser-Tissue Interaction XII: Photochemical, Photothermal, and Photomechanical, (9 July 2001); https://doi.org/10.1117/12.434718
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Fiber lasers

Quantum cascade lasers

Tissues

Laser cutting

Absorption

Laser dentistry

Laser tissue interaction

Back to Top