Paper
14 September 2001 UV cleaning of contaminated 157-nm reticles
Theodore M. Bloomstein, Vladimir Liberman, Mordechai Rothschild, N. N. Efremow Jr., D. E. Hardy, Stephen T. Palmacci
Author Affiliations +
Abstract
A UV-lamp-based cleaning station, serving as a load-lock to a VUV spectrometer, has been used to evaluate the cleaning of hydrocarbon residues on 157-nm reticles. UV lamp based cleaning is found to be an effective tool to remove both nanometer scale layers of physisorbed and significantly more resilient highly conjugated 'graphitized' layers on the mask substrate. Slight changes in reflectance and surface roughness are observed on the chromium absorber indicating some degree of photo-oxidation is occurring during lamp cleaning.
© (2001) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Theodore M. Bloomstein, Vladimir Liberman, Mordechai Rothschild, N. N. Efremow Jr., D. E. Hardy, and Stephen T. Palmacci "UV cleaning of contaminated 157-nm reticles", Proc. SPIE 4346, Optical Microlithography XIV, (14 September 2001); https://doi.org/10.1117/12.435764
Lens.org Logo
CITATIONS
Cited by 7 scholarly publications and 3 patents.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Oxygen

Reticles

Ultraviolet radiation

Lamps

Spectroscopy

Reflectivity

Surface roughness