Paper
23 March 2001 Airborne thermography for condition monitoring of a public baths building
Mats Mattsson, Erik Hellman, Sven-Ake Ljungberg
Author Affiliations +
Abstract
Airborne and ground-based thermography surveys have been performed in order to detect moisture and energy related problems in the construction of a public swimming bath building. This paper describes the information potential and the advantages and limitations using a standard IR-camera and traditional inspection methods to gather information for retrofit priorities. The damage conditions indicated in the thermal images are confirmed by field inspections and photographic documentation.
© (2001) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Mats Mattsson, Erik Hellman, and Sven-Ake Ljungberg "Airborne thermography for condition monitoring of a public baths building", Proc. SPIE 4360, Thermosense XXIII, (23 March 2001); https://doi.org/10.1117/12.420998
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Thermography

Inspection

Minerals

Infrared radiation

Climatology

Computing systems

Glasses