Paper
17 May 2002 Volume registration of interventional MRI data using needle paths and point landmarks
Roee S. Lazebnik M.D., Michael S. Breen, Tanya L. Lancaster, Sherif G. Nour, Jonathan S. Lewin, David L. Wilson
Author Affiliations +
Abstract
We created a method for three-dimensional registration of medical scanner image volumes to images of physical tissue sections or other volumes, and evaluated its accuracy. The method is applicable for many animal experiments, and we are applying it to evaluate interventional MRI imaging of thermal ablation and to quantify in vivo drug release from a new device for localized, controlled release. The method computes an optimum set of rigid body registration parameters by iterative minimization of the Euclidean distances between automatically generated correspondence points, along manually selected fiducial needle paths, and optional point landmarks. For numerically simulated registrations, using two needle paths over a range of needle orientations, median voxel displacement errors depended only on needle localization error when the angle between needles was at least 15 degrees. For parameters typical of our in vivo experiments, the median error was <EQ0.18 mm. In addition, we determined that the distance objective function was a useful diagnostic for predicting registration quality. To evaluate the registration quality of physical specimens, we computed the misregistration for a needle not considered during the optimization procedure. We registered an ex vivo sheep brain MR volume with another MR volume and tissue section photographs, using various combinations of needle and point landmarks. Registration error was always <EQ0.65 mm for MR-to-MR registrations and <EQ0.9 mm for MR to tissue section registrations. We conclude that our method provides sufficient spatial correspondence to facilitate comparison of 3D image data with data from gross pathology tissue sections and histology.
© (2002) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Roee S. Lazebnik M.D., Michael S. Breen, Tanya L. Lancaster, Sherif G. Nour, Jonathan S. Lewin, and David L. Wilson "Volume registration of interventional MRI data using needle paths and point landmarks", Proc. SPIE 4681, Medical Imaging 2002: Visualization, Image-Guided Procedures, and Display, (17 May 2002); https://doi.org/10.1117/12.466956
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Image registration

Tissues

Magnetic resonance imaging

Photography

Brain

Tissue optics

Medical imaging