PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.
A 15 percent nickel composite was manufactured and tested under a sinusoidally applied magnetic field at a frequency of 0.3 Hz around a DC bias of 0kA/m without an external mechanical load. The particulate are obtained from a process known as spark erosion, resulting in particulate that are nearly spherical in shape. Parameters that were recorded include strain, magnetic field, and magnetic flux. Experimental strain output values were comparable to strain measured from a single crystal nickel along the axis. However, the effects of the epoxy are non-negligible and results regarding texturing of the composite are inconclusive.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.
The alert did not successfully save. Please try again later.
Nersesse Nersessian, Siu Wing Or, Gregory Paul Carman, Harry B. Radousky, "Manufacturing and testing of [1-3] nickel/polymer composites," Proc. SPIE 4699, Smart Structures and Materials 2002: Active Materials: Behavior and Mechanics, (11 July 2002); https://doi.org/10.1117/12.475000