Paper
15 March 2002 Thermal performance of windows by means of thermography and heat-flux meters
Author Affiliations +
Abstract
The replacement of windows is the most common renovation measure in Finland. There are also problems in new buildings especially with new thin light metal-framed windows, even though the U-value of the pane would be acceptable. The minor defects in the installation may cause IAQ-problems - because of seam leaks and thermal bridges. There is no general procedure for condition survey of windows based on measurements. In this paper a procedure for testing windows in in-situ conditions is presented based on case studies. Thermal performance of windows can be measured using thermography and supporting methods, like heat-flux measurements and air leak tests. Even though the absolute results may include interfering factors, we can compare the windows with each other (depending on the conditions) and make decisions on the quality of the installation work and the thermal performance of windows.
© (2002) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Timo T. Kauppinen "Thermal performance of windows by means of thermography and heat-flux meters", Proc. SPIE 4710, Thermosense XXIV, (15 March 2002); https://doi.org/10.1117/12.459574
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Temperature metrology

Glasses

Thermography

Heat flux

Ultrasonics

Bridges

Velocity measurements

Back to Top