26 November 2002 Quasi-monochromatic parallel radiography achieved with a plane-focus x-ray tube
Eiichi Sato, Makoto Komatsu, Yasuomi Hayasi, Etsuro Tanaka, Hidezo Mori, Toshiaki Kawai, Tatsumi Usuki, Koetsu Sato, Toshio Ichimaru, Kazuyoshi Takayama, Hideaki Ido
Author Affiliations +
Abstract
Fundamental study on quasi-monochromatic parallel radiography using a polycapillary plate and a plane-focus x-ray tube is described. The x-ray generator consists of a negative high-voltage power supply, a filament (hot cathode) power supply, and an x-ray tube. The negative high-voltage is applied to the cathode electrode, and the transmission type target (anode) is connected to the ground potential. The maximum voltage and current of the power supply were -100 kV (peak value) and 3.0 mA, respectively. In this experiment, the tube voltage was regulated from 20 to 25 kV, and the tube current was regulated by the filament temperature and ranged from 1.0 to 3.0 mA. The exposure time is controlled in order to obtain optimum film density, and the focal spot diameter was about 10 mm. The polycapillary plate is J5022-21 made by Hamamatsu Photonics Inc., and the outside and effective diameters are 87 and 77 mm, respectively. The thickness and the hole diameter of the polycapillary are 1.0 m and 25 μm, respectively. The x-rays from the t ube are formed into parallel beam by the polycapillary, and the radiogram is taken using an industrial x-ray film of Fuji IX 100 without using a screen. In the measurement of image resolution, we employed three brass spacers of 2, 30, and 60 mm in height. By the test chart, the resolution fell according to increases in the spacer height without using a polycapillary. In contrast, the resolution slightly fell with corresponding increases in the height by the polycapillary. In angiography, fine blood vessels of about 100 μm are clearly visible.
© (2002) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Eiichi Sato, Makoto Komatsu, Yasuomi Hayasi, Etsuro Tanaka, Hidezo Mori, Toshiaki Kawai, Tatsumi Usuki, Koetsu Sato, Toshio Ichimaru, Kazuyoshi Takayama, and Hideaki Ido "Quasi-monochromatic parallel radiography achieved with a plane-focus x-ray tube", Proc. SPIE 4786, Penetrating Radiation Systems and Applications IV, (26 November 2002); https://doi.org/10.1117/12.452290
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
X-rays

Radiography

Image resolution

Power supplies

Capillaries

Molybdenum

Photonics

Back to Top