27 November 2002 Moving array lens technique (MALT) for improved resolution of all-optical three-dimensional projection
Ju-Seog Jang, Bahram Javidi
Author Affiliations +
Abstract
We propose the use of synchronously moving micro-optics (lenslet arrays) for image pickup and display in three-dimensional integral imaging to overcome the upper resolution limit imposed by the Nyquist sampling theorem. With the proposed technique, we present an all-optical three-dimensional integral imaging projector. An optically addressed spatial light modulator is used, which potentially provides better image resolution than the conventional CCD and liquid crystal display pair. We present experimental results using a liquid crystal light valve.
© (2002) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Ju-Seog Jang and Bahram Javidi "Moving array lens technique (MALT) for improved resolution of all-optical three-dimensional projection", Proc. SPIE 4789, Algorithms and Systems for Optical Information Processing VI, (27 November 2002); https://doi.org/10.1117/12.455969