Paper
1 July 2003 Hollow waveguide delivery system for the ophthalmology treatment
Author Affiliations +
Abstract
For the purpose of the ophthalmology treatments a special hollow waveguide based delivery instrument was developed. It consists of a 2 m long cyclic olefin polymer coated silver hollow glass waveguide (inner diameter 700 μm) and the special cap allowing the contact of the waveguide with the wet eye tissues. The transmission characteristics for a delivery of a mid-infrared Er:YAG radiation (2.94 μm) was measured. Then the pre-clinical interaction experiments of the Er:YAG laser radiation with the eye tissue (cornea, lens, and sclera) were performed with this delivery instrument. A comparison of two types of interactions results - the action of Er:YAG free running - 40 μs long pulses and giant 450 ns long pulses were made. The human eye tissues (in vitro) were cut and samples (cornea, lens, and sclera) were gradually irradiated by the mid-infrared radiation with the energy of 7 mJ (the corresponding spot size diameter was equal ~ 700 μm). The laser energy density used in this experiment was 1.8 J/cm2. From results it can be concluded that the giant pulses are more efficient in the ablation of the cornea, they are comparable with the free-running long pulses in the case of lens grinding, and they are less functioning for the sclera perforation. As concern the hollow waveguide delivery system, it has been proved that the energy delivered by this system was sufficient and suitable in both cases for delivery of long - free-running pulses, and short - giant pulses as well.
© (2003) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Helena Jelinkova, Michal Nemec, Jan Sulc, Miroslav Cech M.D., Mitsunobu Miyagi, Katsumasa Iwai, Yi-Wei Shi, Yuji Matsuura, and Jiri Pasta "Hollow waveguide delivery system for the ophthalmology treatment", Proc. SPIE 4957, Optical Fibers and Sensors for Medical Applications III, (1 July 2003); https://doi.org/10.1117/12.478041
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Er:YAG lasers

Tissues

Waveguides

Cornea

Eye

Sclera

Hollow waveguides

RELATED CONTENT

Ablation rate of the human cornea and PMMA with fifth...
Proceedings of SPIE (January 12 1995)
YAG laser in ophthalmology
Proceedings of SPIE (October 15 2002)
Hollow waveguide for urology treatment
Proceedings of SPIE (February 24 2010)
Er YAG laser radiation for soft and hard urological tissue...
Proceedings of SPIE (February 22 2006)

Back to Top