Paper
2 June 2003 Implementation of Reference Measurement System using CD-AFM
Ronald G. Dixson, Angela Guerry, Marylyn Hoy Bennett, Theodore V. Vorburger, Benjamin D. Bunday
Author Affiliations +
Abstract
International SEMATECH (ISMT) and the National Institute of Standards and Technology (NIST) are working together to improve the traceability of atomic force microscope (AFM) dimensional metrology in semiconductor manufacturing. The rapid pace of technological change in the semiconductor industry makes the timely introduction of relevant standards challenging. As a result, the link between the realization of the SI (Systeme International d’Unites, or International System of Units) unit of length - the meter - and measurements on the fab line is not always maintained. To improve this situation, we are using an at-line critical dimension-AFM (CD-AFM) at ISMT as a developmental platform. This tool has been implemented as a Reference Measurement System (RMS) in the facilities at ISMT. However, it is currently being replaced by a next-generation CD-AFM tool. Using the current tool, we have performed measurements needed to establish the traceability chain and developed uncertainty budgets. Specifically, we have developed uncertainty budgets for pitch, height, and critical dimension (CD) measurements. Some evaluations were performed using samples for which a full traceability chain is not available. We expect to improve the uncertainties further for such samples. At present, the standard uncertainties are estimated to be approximately 0.2 % for pitch measurements, 0.4 % for step height measurements, and 5 nm for CD measurements in the sub-micrometer range. Similar budgets will be developed for the new tool once it is installed. We will describe our methodology for RMS implementation and the major applications for which it has been used. These include measurements on new NIST/ISMT linewidth standards, a reference tool for CD-scanning electron microscopes (SEMs), metrology on photo-masks, CD-SEM benchmarking, and 193 nm resist shrinkage measurements.
© (2003) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Ronald G. Dixson, Angela Guerry, Marylyn Hoy Bennett, Theodore V. Vorburger, and Benjamin D. Bunday "Implementation of Reference Measurement System using CD-AFM", Proc. SPIE 5038, Metrology, Inspection, and Process Control for Microlithography XVII, (2 June 2003); https://doi.org/10.1117/12.483667
Lens.org Logo
CITATIONS
Cited by 23 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Semiconducting wafers

Scanning electron microscopy

Standards development

Calibration

Atomic force microscopy

Metrology

Critical dimension metrology

RELATED CONTENT

Reference metrology using a next-generation CD-AFM
Proceedings of SPIE (May 24 2004)
Submicron calibration strategy for CD control
Proceedings of SPIE (September 13 1996)
CD-AFM reference metrology at NIST and SEMATECH
Proceedings of SPIE (May 10 2005)

Back to Top