You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
22 July 2003Four-point calibration of PVDF sensor using extrinsic Fabry-Perot interferometric sensors
The performance of sensor systems in smart structures is subject to orientation, installation, and environmental effects. The capability for initial and maintenance calibrations can provide added confidence in sensor information and facilitate investigations of long-term sensor behavior. The use of Extrinsic Fabry-Perot Interferometric (EFPI) fiber-optic sensors was examined for calibration of companion strain sensors. The output of the EFPI sensor is periodic with strain and the signal behavior with periodic strain displays well-defined harmonic content. In particular, the strains giving maximums and minimums in the harmonics can be calculated from the excitation wavelength and the EFPI gage length. A Polyvinylidene Fluoride (PVDF) piezoelectric strain sensor was surface mounted on a cantilever beam and its voltage-to-strain ratio was precisely calibrated using the accuracy of a co-located EFPI sensor. The experimental responses of both sensors were obtained for a periodic actuation. The PVDF output was calibrated using a linear-fit of the strains obtained from four points in the harmonic response of the reference EFPI sensor. The selected maximum and minimum points of the EFPI harmonics were directly observed with a spectrum analyzer. This fast, efficient approach was performed under resonant conditions with relatively inexpensive demodulation requirements. The results of the calibration compared well with the expected PVDF response.
Abdeq M. Abdi andSteve E. Watkins
"Four-point calibration of PVDF sensor using extrinsic Fabry-Perot interferometric sensors", Proc. SPIE 5050, Smart Structures and Materials 2003: Smart Sensor Technology and Measurement Systems, (22 July 2003); https://doi.org/10.1117/12.484256
The alert did not successfully save. Please try again later.
Abdeq M. Abdi, Steve E. Watkins, "Four-point calibration of PVDF sensor using extrinsic Fabry-Perot interferometric sensors," Proc. SPIE 5050, Smart Structures and Materials 2003: Smart Sensor Technology and Measurement Systems, (22 July 2003); https://doi.org/10.1117/12.484256