10 November 2003 Resume of seven-year MOS in-orbit calibration: events, effects, and explanations
Horst Schwarzer, Birgit Gerasch, Andreas Neumann, Karl-Heinz Sumnich, Thomas Walzel, Gerhard Zimmermann
Author Affiliations +
Abstract
The in-orbit calibration of the Modular Optoelectronic Scanner MOS on the Indian Remote Sensing Satellite IRS-P3 has delivered the actual radiometric recalibration coefficients with sufficient accuracy for most of the 18 spectral channels in the VIS/NIR spectral range during the 7 years mission time. This has been the basis for the thematic interpretation of the MOS data. The three different and independent in-orbit calibration methods: lamp calibration, sun calibration and ground target based (vicarious) calibration as well as different possibilities of dark signal determination and the extensive knowledge of instrument performance data and instrument characteristics from the lab measurements have enabled us to overcome all failures and difficulties of the instrument which occurred in orbit. The failure of the lamp and sun calibration equipment in September 2000 has been overcome by using the vicarious calibration and dark signal measurements at the earth night side at new moon. The failure of the thermo-electric cooling of the detectors in November 2002 could be overcome only by the knowledge of the temperature dependence of the spectral responsivity of the different spectral channels and its dark signals. Thus we are able to continue the determination of the time trend of the recalibration coefficients in spite of these problems. In the paper we will give a resume of the most important events concerning the in-orbit calibration during the mission time, try to find explanations for some effects and present the results of determining the recalibration coefficients and the accuracy reached under the concrete environmental and instrumental conditions in orbit.
© (2003) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Horst Schwarzer, Birgit Gerasch, Andreas Neumann, Karl-Heinz Sumnich, Thomas Walzel, and Gerhard Zimmermann "Resume of seven-year MOS in-orbit calibration: events, effects, and explanations", Proc. SPIE 5151, Earth Observing Systems VIII, (10 November 2003); https://doi.org/10.1117/12.502542
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Calibration

Sun

Molybdenum

Lamps

Sensors

Vignetting

Charge-coupled devices

RELATED CONTENT

Radiation calibration research on multichannel CCD camera
Proceedings of SPIE (January 20 2005)
Onboard calibration status of ASTER
Proceedings of SPIE (October 03 2006)
New results of ground target based calibration of MOS on...
Proceedings of SPIE (September 24 2002)
ASTER on-board calibration status
Proceedings of SPIE (October 09 2008)

Back to Top