Paper
3 February 2004 JEM-X: the x-ray monitor on INTEGRAL
Carl Budtz-Jorgensen, N. Lund, Niels J. Westergaard, S. Brandt, Allan Hornstrup, Ib Lundgaard Rasmussen, S. Laursen, S. M. Pedersen, Rene Engel Kristansen, P. B. Mogensen, K. Harpo Andersen, I. Rasmussen, Josef Polny, P. A. Jensen, C. A. Oxborrow, J. Chenevez, K. Omoe, Veikko J. Kamarainen, Tor Andersson, Osmi R. Vilhu, J. Huovelin, Enrico Costa, Marco Feroci, Alda Rubini, E. Morelli, A. Morbidini, Filippo Frontera, Carlo Pelliciari, G. Loffredo, Guido Zavattini, Vittore Carassiti, M. Morawski, G. Juchnikowski, Victor Reglero, J. Peris, V. Collado, Juana Maria Rodrigo, F. Perez, Jose-Luis Requena, S. Larsson, R. Svensson, A. Zdziarski, A. J. Castro-Tirado, Herbert W. Schnopper
Author Affiliations +
Abstract
The INTEGRAL X-ray monitor, JEM-X, (together with the two gamma ray instruments, SPI and IBIS) provides simultaneous imaging with arcminute angular resolution in the 3-35 keV band. The good angular resolution and low energy response of JEM-X plays an important role in the detection and identification of gamma ray sources as well as in the analysis and scientific interpretation of the combined X-ray and gamma ray data. JEM-X is a coded aperture X-ray telescope consisting of two identical detectors. Each detector has a sensitive area of 500 cm2, and views the sky through its own coded aperture mask. The coded masks are located 3.4 m above the detector windows. The detector field of view is constrained by X-ray collimators (6.6° FOV, FWHM).
© (2004) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Carl Budtz-Jorgensen, N. Lund, Niels J. Westergaard, S. Brandt, Allan Hornstrup, Ib Lundgaard Rasmussen, S. Laursen, S. M. Pedersen, Rene Engel Kristansen, P. B. Mogensen, K. Harpo Andersen, I. Rasmussen, Josef Polny, P. A. Jensen, C. A. Oxborrow, J. Chenevez, K. Omoe, Veikko J. Kamarainen, Tor Andersson, Osmi R. Vilhu, J. Huovelin, Enrico Costa, Marco Feroci, Alda Rubini, E. Morelli, A. Morbidini, Filippo Frontera, Carlo Pelliciari, G. Loffredo, Guido Zavattini, Vittore Carassiti, M. Morawski, G. Juchnikowski, Victor Reglero, J. Peris, V. Collado, Juana Maria Rodrigo, F. Perez, Jose-Luis Requena, S. Larsson, R. Svensson, A. Zdziarski, A. J. Castro-Tirado, and Herbert W. Schnopper "JEM-X: the x-ray monitor on INTEGRAL", Proc. SPIE 5165, X-Ray and Gamma-Ray Instrumentation for Astronomy XIII, (3 February 2004); https://doi.org/10.1117/12.506791
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

X-rays

Collimators

Calibration

X-ray detectors

Particles

Xenon

RELATED CONTENT

JEM-X: three years in space
Proceedings of SPIE (June 15 2006)
The on ground calibrations of SuperAGILE I. X ray...
Proceedings of SPIE (June 15 2006)
Design and calibration of the GOES 8 solar x ray...
Proceedings of SPIE (October 18 1996)
Joint European x ray monitor (JEM X) x ray...
Proceedings of SPIE (October 18 1996)

Back to Top