Paper
30 September 2003 The determination of the pumping temperature for EDFA
Florentin I. Vasile, Paul Schiopu
Author Affiliations +
Abstract
There is presented a simple method to obtain the pumping temperature Tp for EDFA. We propose the analytical method to obtain the pumping temperature for EDFA (Erbium Doped Fiber Amplifier). We have obtained the pumping temperature of EDFA by varying the voltage parameter VTEMP in the following interval VTEMP ε (0 ÷ 2.5). With these sets of values we calculated the pumping temperature Tp of the EDFA as a function of VTEMP.
© (2003) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Florentin I. Vasile and Paul Schiopu "The determination of the pumping temperature for EDFA", Proc. SPIE 5227, Advanced Topics in Optoelectronics, Microelectronics, and Nanotechnologies, (30 September 2003); https://doi.org/10.1117/12.519904