You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
5 May 2004Adaptive cubic interpolation of CT slices for maximum intensity projections
Three-dimensional visualization of medical images, using maximum intensity projection (MIP), requires isotropic volume data for the generation of realistic and undistorted 3-D views. However, the distance between CT slices is usually larger than the pixel spacing within each slice. Therefore, before the MIP operation, these axial slice images must be interpolated for the preparation of the isotropic data set. Of many available interpolation techniques, linear interpolation is most popularly used for such slice interpolation due to its computational simplicity. However, as resulting MIP’s depend heavily upon the variance in interpolated slices (due to the inherent noise), MIP’s of linearly interpolated slices suffer from horizontal streaking artifacts when the projection direction is parallel to the axial slice (e.g., sagittal and coronal views). In this paper, we propose an adaptive cubic interpolation technique to minimize these horizontal streaking artifacts in MIP’s due to the variation of the variance across interpolated slices. The proposed technique, designed for near-constant variance distribution across interpolated slices, will be shown to be superior over the linear interpolation technique by completely eliminating the horizontal streaking artifacts in MIP’s of simulated data set and real CT data set.
The alert did not successfully save. Please try again later.
Junghyun Kwon, Ji-Woong Yi, Samuel M. Song, "Adaptive cubic interpolation of CT slices for maximum intensity projections," Proc. SPIE 5367, Medical Imaging 2004: Visualization, Image-Guided Procedures, and Display, (5 May 2004); https://doi.org/10.1117/12.535075