Paper
6 May 2004 Design and performance of a 32-slice CT detector system using back-illuminated photodiodes
Steve Utrup, Marc Chappo, Brian Harwood, Tony Krecic, Randy P. Luhta, Rod Mattson, Dave Salk, Chris Vrettos
Author Affiliations +
Abstract
A complete 32 slice CT detector system has been constructed which uses back illuminated photodiodes (BIPs). Individual detector modules in the system incorporate the BIPs along with highly integrated A/D conversion electronics on the same substrate. A symmetrical mechanical structure allows the system to be compact and lightweight for use at high rotational speeds. The unique design also has the advantage of having no internal cables. The current BIP exhibits a higher level of crosstalk between photosensitive elements when compared to a conventional photodiode. Differences in the crosstalk level at detector module boundaries can cause artifacts unless the crosstalk can either be reduced or a software correction made. In order to show that the BIP is a viable technology for use in multislice CT, a performance evaluation of the complete BIP system along with its associated mechanical, electrical and software components is required. The 32 slice detector system has been mounted to a rotating CT scanner for image performance evaluations. Measurements of low contrast sensitivity, MTF, limiting resolution and other parameters have been done. A crosstalk correction algorithm has also been developed and evaluated under different conditions. Low contrast sensitivity, MTF and limiting resolution of the system match those of a current conventional CT scanner of similar geometry. The crosstalk correction effectively eliminates artifacts caused by non-uniform crosstalk at module boundaries. MTF and noise properties before and after crosstalk correction match theoretical values.
© (2004) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Steve Utrup, Marc Chappo, Brian Harwood, Tony Krecic, Randy P. Luhta, Rod Mattson, Dave Salk, and Chris Vrettos "Design and performance of a 32-slice CT detector system using back-illuminated photodiodes", Proc. SPIE 5368, Medical Imaging 2004: Physics of Medical Imaging, (6 May 2004); https://doi.org/10.1117/12.534646
Lens.org Logo
CITATIONS
Cited by 10 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Modulation transfer functions

Scanners

Photodiodes

Computed tomography

Back illuminated sensors

X-rays

RELATED CONTENT

Volume CT (VCT) enabled by a novel diode technology
Proceedings of SPIE (April 20 2005)
Silicon drift chamber with extended energy range
Proceedings of SPIE (December 13 2000)
A new 2D-tiled detector for multislice CT
Proceedings of SPIE (March 02 2006)
Back-illuminated photodiodes for multislice CT
Proceedings of SPIE (June 05 2003)

Back to Top