Paper
4 May 2004 Comparison of nodule characteristics on CT and radiographic images
Zhimin Huo, Melisa Gao, David F. Yankelevitz, Claudia I. Henschke, William J. Kostis, John Wandtke
Author Affiliations +
Abstract
The purpose of this study is to identify the difference in nodule characteristics manifested on computed topography (CT) and X-ray images and to evaluate the ability of radiographic features to differentiate between benign and malignant nodules, when compared to the features extracted from CT. We collected 79 consecutive computed radiographic (CR) chest images with one or more CT-documented lung nodules. Upon viewing the CT slices, corresponding nodules were localized on CR images by an experienced chest radiologist. Of the 79 CT nodules (19 benign, 60 malignant), 61 (14 benign, 47 malignant) were considered to be definitely visible on the CR, and the rest were considered to be invisible or did not qualify for distinct feature assessment. Eleven nodule features each were visually extracted from CT and CR images. These features were used to characterize the nodule in terms of size, shape, lobulation, spiculation, density, etc. Correlation between the CT and CR features was calculated for the 61 definitely CR-visible nodules. Receiver operating characteristics (ROC) analysis was performed to evaluate the ability of these features in the task of differentiating between benign and malignant nodules. Results showed that CR and CT images agreed well in characterizing nodules in terms of shape, lobulation, spiculation and density features. We found that 40-50% of the cases had same CR and CT ratings and 41-51% of cases were rated by a difference of one between their ratings on CT and CR for shape (3-point scale), lobulation (4-point scale) and speculation (4-point scale) features. Ninety-two percent of the cases had same CT and CR ratings on the density feature. Size yielded a correlation coefficient of 0.84. In the task of differentiating between benign and malignant lung nodules, ROC analysis of individual features yielded an Az value ranging from 0.52 to 0.77 for the 14 CT features and from 0.52 to 0.75 for the CR features. In addition, we examined the characteristics of the 18 nodules that were excluded from feature analysis. On average, these 18 nodules were smaller in size (15.2 mm measured from CT) than the 61 CR-visible nodules (23.5 mm). We found that CR features agreed reasonably well with CT features and their ability to differentiate between benign and malignant nodules were similar to that of the CT features.
© (2004) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Zhimin Huo, Melisa Gao, David F. Yankelevitz, Claudia I. Henschke, William J. Kostis, and John Wandtke "Comparison of nodule characteristics on CT and radiographic images", Proc. SPIE 5372, Medical Imaging 2004: Image Perception, Observer Performance, and Technology Assessment, (4 May 2004); https://doi.org/10.1117/12.537363
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Chromium

Computed tomography

X-ray computed tomography

Lung

Chest

Feature extraction

Solids

Back to Top