Paper
12 October 2004 Optimizing cryogen utilization on Spitzer Space Telescope
Author Affiliations +
Abstract
The instruments of the Spitzer Space Telescope are cooled directly by liquid helium, while the optical system is cooled by helium vapor. The greater the power dissipation into the liquid helium, the more vapor is produced, and the colder the telescope. Observations at shorter wavelengths do not require telescope temperatures as low as those required at longer wavelengths. By varying the telescope temperature with observing wavelength, we are extending the mission lifetime by an estimated 9%.
© (2004) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Charles R. Lawrence and Paul T. Finley "Optimizing cryogen utilization on Spitzer Space Telescope", Proc. SPIE 5487, Optical, Infrared, and Millimeter Space Telescopes, (12 October 2004); https://doi.org/10.1117/12.551949
Lens.org Logo
CITATIONS
Cited by 5 scholarly publications.