7 June 2005 Excimer laser with repetition rate up to 2000 Hz
G. P. Kuzmin, V. K. Bashkin, V. G. Dobkin, S. M. Babichenko
Author Affiliations +
Proceedings Volume 5850, Advanced Laser Technologies 2004; (2005) https://doi.org/10.1117/12.633719
Event: Advanced Laser Technologies 2004, 2004, Rome and Frascati, Italy
Abstract
Laser medical device "Maria" on the basis of KrF excimer laser with the wavelength 248 nm was made for fiber-cavernous lung tuberculosis and bronchia tuberculosis treatment. This very spectral range has maximum efficiency due to the peak of micro bacteria destruction. The main difficulty in the operation with 248 nm radiations arises in the transportation of the radiation from the laser into a tuberculosis cavern along a fiber light guide. The necessity to obtain the desirable mean power of the radiation with a low frequency of pulses it is necessary to increase the peak power in the pulse, which leads us to the destruction of the light guide. In order to bypass this restriction a unique excimer laser was developed. In this laser generation was exited with a discharge propagate along the surface of the dielectric, namely the sliding discharge. High pulse repetition rate was obtained by the thick plasma layer (thickness about 1-1.5 mm) formation by the sliding discharge, which actually use as the pumping source. The sliding discharge plasma propagates along the sapphire plate placed on massive metallic electrode. This provides the optimum conditions for electrode cooling and gives us the increase of the generation repetition rate. The sliding discharge used as pumping source for excimer KrF laser gives us the possibility to obtain the repetition rate up to 2000 Hz without replacing the gaseous mixture. At this condition and the mean power of the generation about 20 mW (pulse duration about 10ns) the peak power was about 1 kW. This gives us the possibility to transport the UV radiation into the cavern without wave-guide destruction. This excimer laser was able to work continuously during 3 hours without replacing the gaseous mixture. This opens wide possibilities to apply excimer lasers into the medical practice.
© (2005) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
G. P. Kuzmin, V. K. Bashkin, V. G. Dobkin, and S. M. Babichenko "Excimer laser with repetition rate up to 2000 Hz", Proc. SPIE 5850, Advanced Laser Technologies 2004, (7 June 2005); https://doi.org/10.1117/12.633719
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Excimer lasers

Electrodes

Ultraviolet radiation

Dielectrics

Medical devices

Medical laser equipment

Plasma

RELATED CONTENT

A new DBD driven atmospheric pressure plasma jet source on...
Proceedings of SPIE (December 15 2015)
XeCl laser with LC-circuit excitation research
Proceedings of SPIE (August 01 1991)
Planar sliding discharge-driven UV excimer light source
Proceedings of SPIE (March 23 2005)
Ultraviolet Waveguide Lasers
Proceedings of SPIE (June 01 1989)
Excitation of an excimer laser with microwave resonator
Proceedings of SPIE (September 01 1991)

Back to Top