Paper
8 September 2005 Experimental set-up for testing alignment and measurement stability of a metrology system in silicon carbide for GAIA
Marielle van Veggel, Arno Wielders, Hedser van Brug, Nick Rosielle, Henk Nijmeijer
Author Affiliations +
Proceedings Volume 5877, Optomechanics 2005; 587701 (2005) https://doi.org/10.1117/12.614031
Event: Optics and Photonics 2005, 2005, San Diego, California, United States
Abstract
The GAIA satellite will make a 3-D map of our Galaxy with measurement accuracy of 10 microarcseconds using two astrometric telescopes. The angle between the lines-of-sight of the two telescopes will be monitored using the Basic Angle Monitoring system with 1 microarcsecond accuracy. This system will be an interferometer consisting of a number of small mirrors and beam splitters in Silicon Carbide. Silicon Carbide has very high specific stiffness and very good thermal properties (low CTE and high conductivity). It also is a very stable material. A possible concept design for this Basic Angle Monitoring system is subject of a PhD study performed at the Technische Universiteit Eindhoven and TNO Science and Industry (The Netherlands). To prove that this concept design meets the alignment and measurement stability requirements, the GAIA extreme stability optical bench is developed. It will consist of a fourfold Michelson interferometer with four separate optical paths, which will measure the stability of the optical bench and the individual optical components. Also thermal cycling experiments and vibrations tests will be performed. 'Absolute' position measurements of the optical components with respect to the optical bench after the vibrations test will be performed using markers. The GAIA extreme stability optical bench will be placed in a vibration damped vacuum tank in order to imitate the highly stable L2 space environment. The goal is to obtain the first results early 2006.
© (2005) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Marielle van Veggel, Arno Wielders, Hedser van Brug, Nick Rosielle, and Henk Nijmeijer "Experimental set-up for testing alignment and measurement stability of a metrology system in silicon carbide for GAIA", Proc. SPIE 5877, Optomechanics 2005, 587701 (8 September 2005); https://doi.org/10.1117/12.614031
Lens.org Logo
CITATIONS
Cited by 4 scholarly publications and 1 patent.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Optical benches

Mirrors

Beam splitters

Optical components

Telescopes

Optical alignment

Silicon carbide

RELATED CONTENT

PANIC in the lab: status before commissioning
Proceedings of SPIE (July 08 2014)
The AIV concept of SHARK NIR, a new coronagraph for...
Proceedings of SPIE (July 27 2018)
Flight configuration for the small optical user terminal
Proceedings of SPIE (August 16 1994)
Realization of the MIDI cold optics
Proceedings of SPIE (February 21 2003)

Back to Top