You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
17 March 2006A study on the performance evaluation of computer-aided diagnosis for detecting pulmonary nodules for the various CT reconstruction
The purpose of this study was to evaluate the performance of computer-aided diagnosis (CAD) system detecting pulmonary nodules for the various CT image qualities of the low dose CT cancer screening. Sixty three chest examinations with sixty-four pulmonary nodules consisting mainly ground-glass opacity (GGO) were used. All the CT images were acquired by using a multi-slice CT scanner Asteion with 4 detector rows system (Toshiba Medical Systems, Japan) with 0.75-second rotating time and 30mA. After the examination, CT image reconstructions were performed for every CT data set using seven reconstruction kernels and three sorts of slice thickness. Totally twenty-one data sets for a patient, namely 1323 data sets with about 60 thousands CT images which is 30.1GB data sets were investigated. Nodule detections were carried out using a computer-aided diagnosis system developed by Fujitsu Ltd, Japan. The mean nodule size was 0.69±0.28 (SD)[cm](range, 0.3-1.7cm). The CAD system identified 42 to 48 nodules out of the 64 nodules, in the slice thickness of 8mm for the seven reconstruction kernels, yielding a true-positive rate (TPR) of 65% to 75%. In the slice thickness of 5mm our CAD system indicates a TPR from 70% to 80%. In the slice thickness 10mm, TPR were resulted from 50% to 64%. Some kernel indicated relatively high TPR with high FP, other kernel showed high sensitivity with relatively low FP. CT image data sets with multi-reconstruction conditions is useful in assessing the robust characteristics of a CAD system detecting pulmonary nodule by multi-slice low dose CT screening.
Shinichi Wada,Toru Matsumoto,Kohei Murao, andShusuke Sone
"A study on the performance evaluation of computer-aided diagnosis for detecting pulmonary nodules for the various CT reconstruction", Proc. SPIE 6146, Medical Imaging 2006: Image Perception, Observer Performance, and Technology Assessment, 61461C (17 March 2006); https://doi.org/10.1117/12.654418
The alert did not successfully save. Please try again later.
Shinichi Wada, Toru Matsumoto, Kohei Murao, Shusuke Sone, "A study on the performance evaluation of computer-aided diagnosis for detecting pulmonary nodules for the various CT reconstruction," Proc. SPIE 6146, Medical Imaging 2006: Image Perception, Observer Performance, and Technology Assessment, 61461C (17 March 2006); https://doi.org/10.1117/12.654418