You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
19 May 2006Biological agent detection based on principal component analysis
This paper presents an algorithm, based on principal component analysis for the detection of biological threats using
General Dynamics Canada's 4WARN Sentry 3000 biodetection system. The proposed method employs a statistical
method for estimating background biological activity so as to make the algorithm adaptive to varying background
situations. The method attempts to characterize the pattern of change that occurs in the fluorescent particle counts
distribution and uses the information to suppress false-alarms. The performance of the method was evaluated using a
total of 68 tests including 51 releases of Bacillus Globigii (BG), six releases of BG in the presence of obscurants, six
releases of obscurants only, and five releases of ovalbumin at the Ambient Breeze Tunnel Test facility, Battelle, OH.
The peak one-minute average concentration of BG used in the tests ranged from 10 - 65 Agent Containing Particles per
Liter of Air (ACPLA). The obscurants used in the tests included diesel smoke, white grenade smoke, and salt solution.
The method successfully detected BG at a sensitivity of 10 ACPLA and resulted in an overall probability of detection of
94% for BG without generating any false-alarms for obscurants at a detection threshold of 0.6 on a scale of 0 to 1. Also,
the method successfully detected BG in the presence of diesel smoke and salt water fumes. The system successfully
responded to all the five ovalbumin releases with noticeable trends in algorithm output and alarmed for two releases at
the selected detection threshold.
The alert did not successfully save. Please try again later.
Naga R. Mudigonda, Ray Kacelenga, "Biological agent detection based on principal component analysis," Proc. SPIE 6218, Chemical and Biological Sensing VII, 62180P (19 May 2006); https://doi.org/10.1117/12.669522