Paper
13 October 2006 The assessing method of complete tooth form error based on the spline function
Fugui Huang, Changcai Cui, Rencheng Zhang
Author Affiliations +
Proceedings Volume 6280, Third International Symposium on Precision Mechanical Measurements; 62802G (2006) https://doi.org/10.1117/12.716374
Event: Third International Symposium on Precision Mechanical Measurements, 2006, Urumqi, China
Abstract
Having analyzed the shortcoming of current measurement method of involute cylinder gear wheel tooth form error and the reason of error, measurement theory and implementation method of the complete tooth form error of the involute cylindrical gear have been proposed; mathematical model of fitting actual tooth curve based on cubic spline function has been derived and the determination of boundary condition has been given; feasibility of measurement and evaluation method for complete tooth form error has been verified by experiment.
© (2006) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Fugui Huang, Changcai Cui, and Rencheng Zhang "The assessing method of complete tooth form error based on the spline function", Proc. SPIE 6280, Third International Symposium on Precision Mechanical Measurements, 62802G (13 October 2006); https://doi.org/10.1117/12.716374