You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
8 September 2006Accurate modeling and experimental validation of a singlemode 4 W output power double cladding erbium ytterbium fibre amplifier
We developed a model that accurately predicts the performances of high power double cladding erbium ytterbium fibre
amplifiers. We experimentally validate the model in co- and counter-propagation configuration for different pump
wavelengths and fibre lengths. By adjusting the ytterbium to erbium cross-relaxation rate with a simple amplifier
experiment, we obtained a complete agreement between the model predictions and the experimental data regarding the
output signal. We measured that the McCumber relationship considerably overestimates the ytterbium emission crosssection;
with a correction of this parameter, we obtained an excellent prediction of the ytterbium spontaneous emission at
1.0 μm. The model is valid for high power singlemode amplifiers as we obtained a full agreement for a 4W output power amplifier from a seed signal of 8 mW at 1556nm. The output was diffraction limited with a measured M2 parameter of
1.03 without doing any mode selection from a slightly multimode fibre with a core diameter of 10 μm and a numerical
aperture of 0.18.
The alert did not successfully save. Please try again later.
Bertrand Morasse, Carl Hovington, Stéphane Chatigny, Michel Piché, "Accurate modeling and experimental validation of a singlemode 4 W output power double cladding erbium ytterbium fibre amplifier," Proc. SPIE 6343, Photonics North 2006, 63430L (8 September 2006); https://doi.org/10.1117/12.707665