You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
1 November 2007Experimental study of response time of magnetorheological fluid damper
In this paper, the response time of one magnetorheological fluid (MR) damper with maximum damping force of 250kN
was tested. Experimental results show that, when electric current increase, response time is about 0.1 to 0.3s; when
current decrease and not to zero, response time is about 0.2 to 0.3s, higher change of current induce longer of response
time. Experimental results also show that, when electric current decrease to zero, response time is about 0.6 to 0.7s,
which is much longer than expected. Further experiment results show that, if subtracting response of coil, when current
increase, the response time is about 60 to 70ms, when current decrease and not to zero, the response time is about 140 to
150ms.