Paper
15 March 2007 A new paradigm in portal imaging QA: fast measurements of modulation transfer function (MTF) and detective quantum efficiency (DQE) using line-pair bar-patterns
Author Affiliations +
Abstract
In portal imaging, the role of electronic portal imaging devices (EPIDs) to implement complex radiation therapy protocols is crucial, and regular quality assurance (QA) of EPID image quality is necessary to ensure treatment efficacy. The modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) are universal metrics that can completely describe radiographic image quality. These metrics are independent of measurement geometry and the user, and allow intra and inter detector performance evaluation. Though NPS and DQE calculations are straightforward, conventional MTF measurements using slit/edge phantoms are difficult and time consuming. Therefore, such measurements are not feasible within routine clinical QA. Currently, EPID performance is monitored using image quality indices obtained from commercial QA phantoms. Such methods may be qualitative or sensitive to imaging conditions, and hence not appropriate for rigorous QA. In this work, a simple and quick method for EPID QA is presented based on a line-pair bar-pattern for fast MTF measurement, coupled with standard NPS and DQE measurements, all of which can be carried out within two minutes. The method to determine MTF from line-pair modulations was developed based on theoretical analyses and Monte Carlo simulations to identify accurate and reliable measurement conditions. The bar-pattern based QA method was tested with two clinical EPIDs and found to be in excellent agreement with slit/edge measurements. It was also implemented for weekly QA checks, and compared with established commercial QA methods. This bar-pattern based QA was more sensitive to potential decrease of EPID image quality.
© (2007) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Arun Gopal and Sanjiv S. Samant "A new paradigm in portal imaging QA: fast measurements of modulation transfer function (MTF) and detective quantum efficiency (DQE) using line-pair bar-patterns", Proc. SPIE 6510, Medical Imaging 2007: Physics of Medical Imaging, 651048 (15 March 2007); https://doi.org/10.1117/12.713704
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Modulation transfer functions

Image quality

Sensors

Modulation

Spatial resolution

Imaging systems

Spatial frequencies

RELATED CONTENT

Measurement of the HYDICE system MTF from flight imagery
Proceedings of SPIE (November 06 1996)
Using visible SNR (vSNR) to compare the image quality of...
Proceedings of SPIE (January 18 2010)
Evaluation procedure for imaging in web inspection
Proceedings of SPIE (January 06 1994)
Video Image Quality And Facial Recognition
Proceedings of SPIE (February 20 1973)
Quality control for on-line portal imaging systems
Proceedings of SPIE (June 30 1993)

Back to Top