You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
5 April 2007Advanced process control for hyper-NA lithography based on CD-SEM measurement
With the recent introduction of immersion lithography, optical systems with numerical aperture (NA) reaching 1.0 or
larger can be realized. Various Resolution Enhancement Techniques (RET) such as various phase shift mask approaches
have been used to push even further the resolution limit by reducing k1 scaling factor, including Double Patterning
Technology. However, with the improved resolution by Hyper-NA and Low-k1, lithographers face the problem of
decreasing Depth of Focus and in turn reduced process latitude. Throughout the industry, Process Window has been
widely used as an analytical tool to evaluate process latitude for a given design feature size; therefore, the ability to
accurately and efficiently derive a Process Window within which a process can run on target and in control is
fundamental to Low-k1 lithography. Accuracy of Process Window derivation is based on the ability to accurately
measure and model the physical dimension of the design feature and how it changes in response to changes in process
parameters. In the case of lithography, the Process Window of a desired critical dimension target is bounded by
changes in exposure energy and defocus. To be able to accurately measure the physical dimension of the design
feature remains a big challenge for metrologists especially in the presence of other process noise. In this work, it is
shown that the precision of PW measurement can be enhanced by using CD-ACD (Average CD) function to measure a
FEM (Focus-Exposure matrix) wafer. ACD is a function, which simultaneously measures several points, thus
providing higher precision measurement in comparison to the conventional single point measurement. As seen in this
work, by using ACD measurements to derive the Process Window, there is a significantly improvement in the stability
of the derived Process Window. Also reported is the MPPC (Multiple Parameters Profile Characterization) *1), a
function which provides the ability to extract pattern shape information from a measured e-beam signal. This function
together with the ACD function enables PW measurement with high precision, which also takes into account the actual
pattern shape. PW derived from conventionally measured data was compared with PW derived from ACD and MPPC
measurement and we were able to demonstrate an improvement of more than 30% in precision of PW determination.
The alert did not successfully save. Please try again later.
T. Ishimoto, K. Sekiguchi, N. Hasegawa, T. Maeda, K. Watanabe, G. Storms, D. Laidler, S. Cheng, "Advanced process control for hyper-NA lithography based on CD-SEM measurement," Proc. SPIE 6518, Metrology, Inspection, and Process Control for Microlithography XXI, 65182P (5 April 2007); https://doi.org/10.1117/12.710814