Paper
14 May 2007 Life test result of Ricor K529N 1watt linear cryocooler
Author Affiliations +
Abstract
The authors summarize the results of the accelerated life testing of the Ricor type K529N 1 Watt linear split Stirling cooler. The test was conducted in the period 2003-2006, during which the cooler accumulated in excess of 27,500 working hours at an elevated ambient temperature, which is equivalent to 45,000 hours at normal ambient conditions, and performed about 7,500 operational cycles including cooldown and steady-state phases. The cryocooler performances were assessed through the cooldown time and power consumption; no visible degradation in performances was observed. After the cooler failure and the compressor disassembling, an electrical short was discovered in the driving coil. The analysis has shown that the wire insulating varnish was not suitable for such elevated temperatures. It is important to note that the cooler under test was taken from the earliest engineering series; in the later manufacturing line military grade wire with high temperature insulation was used, no customer complaints have been recorded in this instance Special attention was paid to the thorough examination of the technical condition of the critical components of the cooler interior. In particular, dynamic piston-cylinder seal, flying leads, internal O-rings and driving coil were examined in the compressor. As to the cold head, we focused on studying the conditions of the dynamic bushing-plunger seal, O-rings and displacer-regenerator. In addition, a leak test was performed to assess the condition of the metallic crushed seals. From the analysis, the authors draw the conclusion that the cooler design is adequate for long life performance (in excess of 20,000 working hours) applications.
© (2007) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Ilan Nachman, Alexander Veprik, and Nachman Pundak "Life test result of Ricor K529N 1watt linear cryocooler", Proc. SPIE 6542, Infrared Technology and Applications XXXIII, 65422G (14 May 2007); https://doi.org/10.1117/12.718364
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Cryocoolers

Head

Accelerated life testing

Lead

Manufacturing

Electrical breakdown

Reliability

RELATED CONTENT

Disruptive cryocoolers for commercial IR imaging
Proceedings of SPIE (May 27 2022)
10-year update of Stirling cryogenic coolers in France
Proceedings of SPIE (December 15 2000)
Miniature integrated dewar/cooler assembly
Proceedings of SPIE (September 01 1990)
Update on life time test results and analysis carried out...
Proceedings of SPIE (January 23 2003)

Back to Top