Paper
14 September 2007 Vertically configured collimator for cryogenic vacuum testing of meter scale optical systems
Derek Sabatke, Steve Meyer, Noah Siegel, Don Byrd, Peter Spuhler, Paul Atcheson, Mark Martella, Edwin Penniman
Author Affiliations +
Abstract
Ball Aerospace has constructed a new collimator for interferometric and image quality testing of meter scale optical systems under cryogenic, vacuum conditions. Termed the Vertical Collimator Assembly (VCA), it features 1.5 m diameter off-axis parabolic and calibration flat mirrors. In order to preserve as large a volume as possible for the unit under test, the main platform is suspended inside its vacuum chamber by a hexapod, with the parabolic mirror mounted overhead. A simultaneous interferometer facilitates collimator alignment and monitoring, as well as wavefront quality measurements for the test unit. Diffusely illuminated targets may be employed for through-focus image quality measurements with pinholes and bar targets. Mechanical alignment errors induced by thermal and structural perturbations are monitored with a three-beam distance measuring interferometer to enable mid-test compensation. Sources for both interferometer systems are maintained at atmospheric pressure while still directly mounted to the main platform, reducing vibration and stability problems associated with thermal vacuum testing. Because path lengths inside the ambient pressure vessels are extremely short, problems related to air turbulence and layering are also mitigated. In-chamber support equipment is insulated and temperature controlled, allowing testing while the chamber shrouds and test unit are brought to cryogenic temperatures.
© (2007) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Derek Sabatke, Steve Meyer, Noah Siegel, Don Byrd, Peter Spuhler, Paul Atcheson, Mark Martella, and Edwin Penniman "Vertically configured collimator for cryogenic vacuum testing of meter scale optical systems", Proc. SPIE 6671, Optical Manufacturing and Testing VII, 667108 (14 September 2007); https://doi.org/10.1117/12.731423
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Interferometers

Collimators

Mirrors

Wavefronts

Calibration

Cryogenics

Beam splitters

RELATED CONTENT

Novel technique for aligning paraboloids
Proceedings of SPIE (January 01 1992)
A laser speckle reduction system
Proceedings of SPIE (September 21 2011)
The Gemini Planet Imager calibration testbed
Proceedings of SPIE (August 19 2009)
Design and development of a cryogenic Michelson interferometer
Proceedings of SPIE (September 17 2007)

Back to Top