Translator Disclaimer
Paper
5 October 2007 VIIRS ZEMAX and FORTRAN polarization models
Author Affiliations +
Abstract
The Visible/Infrared Imager/Radiometer Suite (VIIRS) collects visible/infrared imagery and radiometric data. The radiometric requirements are such that the instrument's polarization sensitivity must be very well understood. This paper presents the ZEMAX and FORTRAN polarization ray trace models of the instrument's visible light path. This will include the measured optical surface reflectance data, the band pass shapes and a comparison of the results of the two models.
© (2007) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Eugene Waluschka, Kenneth Voss, David Moyer, Gerhard Meister, and Lushalan Liao "VIIRS ZEMAX and FORTRAN polarization models", Proc. SPIE 6677, Earth Observing Systems XII, 66770A (5 October 2007); https://doi.org/10.1117/12.735652