You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
20 September 2007SIMBOL-X: the problem of the calibrating a 0.5-80 keV 20m focal length focussing telescope
Simbol-X is a hard X-ray telescope being developed by France and Italy, with the participation of Germany, that will
operate in the 0.5-80 keV. Simbol-X will allow, in the key 10-40 keV band, a two order of magnitude leap both in
sensitivity and angular resolution, by means of a hybrid focal plane coupled with a 20m focal length multi-layer coated
X-ray mirrors. The novel telescope architecture and its three-decade extended energy band translate however into
technical issues never addressed before for what concerns the on-ground calibrations. In fact, at least in the full-illumination
geometry, the unprecedented focal length causes, due to the calibration source finite distance, two main
problems: (a) a non-negligible increase of the fraction of incident photons undergoing only one reflection (in the
parabola); (b) a variation of the reflectivity curve between parabola and hyperbola, due to a corresponding variation of
the incidence angle of incoming photons. In this work, the issue of calibrating a 20m X-ray focussing telescope is
addressed in details, and technical solutions are envisaged and proposed to tackle and minimized the above mentioned
problems.
The alert did not successfully save. Please try again later.
S. Basso, D. Spiga, G. Pareschi, O. Citterio, G. Malaguti, W. Burkert, M. Freyberg, "SIMBOL-X: the problem of the calibrating a 0.5-80 keV 20m focal length focussing telescope," Proc. SPIE 6688, Optics for EUV, X-Ray, and Gamma-Ray Astronomy III, 66880J (20 September 2007); https://doi.org/10.1117/12.733979