You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
27 November 2007Detection method and experimental study for pollutant content based on surface plasmon resonance biosensor
The principle of SPR biosensor is presented at the beginning of this paper. Then both direct assay for macromolecules and indirect assay (inhibition assay) for small molecules are introduced, which allow for high sensitive SPR detection of these two kinds of molecules. By combining some peripheral components including flow cell, multiposition valve, constant flowrate syringe pump and so on, a SPR biosensor system with an integrated miniature SPR sensor was designed and produced. Solutions of different concentrations of bovine serum albumin (BSA) were detected by making use of this system with the method of direct assay and a sensorgram of SPR resonance angle about different concentrations of BSA antibodies was generated. A calibration curve of BSA antibodies was also obtained. Solutions of different concentrations of estradiols were detected using inhibition assay. According to SPR resonance angle shift (ΔRU) corresponding to different concentrations of estradiols, a calibration curve was generated and the result was satisfying. For the sample of unknown concentration, once the resonance angle shift (ΔRU) is detected, the concentration can be calculated from the calibration curve.
Guangcan Zhao,Xiaoping Wang, andXuejiao Zhang
"Detection method and experimental study for pollutant content based on surface plasmon resonance biosensor", Proc. SPIE 6723, 3rd International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, 67232Q (27 November 2007); https://doi.org/10.1117/12.783326
The alert did not successfully save. Please try again later.
Guangcan Zhao, Xiaoping Wang, Xuejiao Zhang, "Detection method and experimental study for pollutant content based on surface plasmon resonance biosensor," Proc. SPIE 6723, 3rd International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, 67232Q (27 November 2007); https://doi.org/10.1117/12.783326