29 February 2008 A comparison of avalanche photodiode and photomultiplier tube detectors for flow cytometry
William G. Lawrence, Gyula Varadi, Gerald Entine, Edward Podniesinski, Paul K. Wallace
Author Affiliations +
Abstract
Commercial flow cytometers use photomultiplier tubes (PMTs) for fluorescence detection. These detectors have high linear gain and broad dynamic range, but have limited sensitivity in the red and near infrared spectral regions. We present a comparison of avalanche photodiodes (APDs) and PMTs as detectors in flow cytometry instruments, and demonstrate improved sensitivity and resolution in the red and near infrared spectral regions using the APD. The relative performance of the PMT and APD were evaluated by simultaneously measuring the mean fluorescence intensity and coefficient of variation for emission from light emitting diode pulses, flow cytometry test beads, and fluorescently labeled cells. The relative signal to noise performance of the APD and PMT was evaluated over the 500 nm to 1050 nm wavelength range using pulsed light emitting diode light sources. While APDs have higher quantum efficiency but lower internal gain than PMTs, with appropriate external amplification the APD has signal to noise response that is comparable to PMTs in the 500 nm to 650 nm range and improved response in the 650 nm to 850 nm range The data demonstrates that the APD had performance comparable to the PMT in the spectral region between 500 to 650 nm and improved performance in the range of 650 to 1000 nm, where the PMT performance is quite poor. CD4 positive lymphocyte populations were easily identified in normal human blood both by APD and PMT using phycoerythrin labeled antibodies. In contrast, only the APD detector could resolve CD4 positive populations using 800 nm Quantum dot labeled antibodies.
© (2008) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
William G. Lawrence, Gyula Varadi, Gerald Entine, Edward Podniesinski, and Paul K. Wallace "A comparison of avalanche photodiode and photomultiplier tube detectors for flow cytometry", Proc. SPIE 6859, Imaging, Manipulation, and Analysis of Biomolecules, Cells, and Tissues VI, 68590M (29 February 2008); https://doi.org/10.1117/12.758958
Lens.org Logo
CITATIONS
Cited by 11 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Avalanche photodetectors

Sensors

Flow cytometry

Signal to noise ratio

Quantum efficiency

Luminescence

Avalanche photodiodes

Back to Top