Paper
11 March 2008 Semi-automatic detection of Gd-DTPA-saline filled capsules for colonic transit time assessment in MRI
Christian Harrer, Sonja Kirchhoff M.D., Andreas Keil, Chlodwig Kirchhoff M.D., Thomas Mussack M.D., Andreas Lienemann M.D., Maximilian Reiser M.D., Nassir Navab
Author Affiliations +
Abstract
Functional gastrointestinal disorders result in a significant number of consultations in primary care facilities. Chronic constipation and diarrhea are regarded as two of the most common diseases affecting between 2&percent; and 27&percent; of the population in western countries1-3. Defecatory disorders are most commonly due to dysfunction of the pelvic floor or the anal sphincter. Although an exact differentiation of these pathologies is essential for adequate therapy, diagnosis is still only based on a clinical evaluation1. Regarding quantification of constipation only the ingestion of radio-opaque markers or radioactive isotopes and the consecutive assessment of colonic transit time using X-ray or scintigraphy, respectively, has been feasible in clinical settings4-8. However, these approaches have several drawbacks such as involving rather inconvenient, time consuming examinations and exposing the patient to ionizing radiation. Therefore, conventional assessment of colonic transit time has not been widely used. Most recently a new technique for the assessment of colonic transit time using MRI and MR-contrast media filled capsules has been introduced9. However, due to numerous examination dates per patient and corresponding datasets with many images, the evaluation of the image data is relatively time-consuming. The aim of our study was to develop a computer tool to facilitate the detection of the capsules in MRI datasets and thus to shorten the evaluation time. We present a semi-automatic tool which provides an intensity, size10, and shape-based11,12 detection of ingested Gd-DTPA-saline filled capsules. After an automatic pre-classification, radiologists may easily correct the results using the application-specific user interface, therefore decreasing the evaluation time significantly.
© (2008) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Christian Harrer, Sonja Kirchhoff M.D., Andreas Keil, Chlodwig Kirchhoff M.D., Thomas Mussack M.D., Andreas Lienemann M.D., Maximilian Reiser M.D., and Nassir Navab "Semi-automatic detection of Gd-DTPA-saline filled capsules for colonic transit time assessment in MRI", Proc. SPIE 6914, Medical Imaging 2008: Image Processing, 69143K (11 March 2008); https://doi.org/10.1117/12.769867
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Image segmentation

Magnetic resonance imaging

Principal component analysis

Image resolution

Clouds

Human-machine interfaces

Image classification

Back to Top