Paper
22 July 2008 Characterization of DECam focal plane detectors
H. Thomas Diehl, Robert Angstadt, Julia Campa, Herman Cease, Greg Derylo, John H. Emes, Juan Estrada, Donna Kubik, Brenna L. Flaugher, Steve E. Holland, Michelle Jonas, William F. Kolbe, John Krider, S. Kuhlmann, Kevin Kuk, Marino Maiorino, Nick Palaio, Andres Plazas, Natalie A. Roe, Vic Scarpine, Ken Schultz, Terri Shaw, Hal Spinka, Walter Stuermer
Author Affiliations +
Abstract
DECam is a 520 Mpix, 3 square-deg FOV imager being built for the Blanco 4m Telescope at CTIO. This facility instrument will be used for the "Dark Energy Survey" of the southern galactic cap. DECam has chosen 250 μm thick CCDs, developed at LBNL, with good QE in the near IR for the focal plane. In this work we present the characterization of these detectors done by the DES team, and compare it to the DECam technical requirements. The results demonstrate that the detectors satisfy the needs for instrument.
© (2008) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
H. Thomas Diehl, Robert Angstadt, Julia Campa, Herman Cease, Greg Derylo, John H. Emes, Juan Estrada, Donna Kubik, Brenna L. Flaugher, Steve E. Holland, Michelle Jonas, William F. Kolbe, John Krider, S. Kuhlmann, Kevin Kuk, Marino Maiorino, Nick Palaio, Andres Plazas, Natalie A. Roe, Vic Scarpine, Ken Schultz, Terri Shaw, Hal Spinka, and Walter Stuermer "Characterization of DECam focal plane detectors", Proc. SPIE 7021, High Energy, Optical, and Infrared Detectors for Astronomy III, 702107 (22 July 2008); https://doi.org/10.1117/12.790053
Lens.org Logo
CITATIONS
Cited by 24 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Charge-coupled devices

Quantum efficiency

Sensors

Diffusion

Photons

Clocks

Electrons

RELATED CONTENT

Focal plane detectors for Dark Energy Camera (DECam)
Proceedings of SPIE (July 15 2010)
CCD detector upgrade for NOAO's 8192x8192 Mosaic
Proceedings of SPIE (July 09 1998)
X-Ray CCD Cameras II: A Versatile Laboratory System
Proceedings of SPIE (April 09 1987)
Open Pinned-Phase CCD Technology
Proceedings of SPIE (November 27 1989)

Back to Top