A clinical treatment delivery platform has been developed for providing 3D controlled hyperthermia with catheter-based ultrasound applicators in conjunction with high dose rate (HDR) brachytherapy. This integrated system consists of hardware and software components required for thermal therapy delivery, treatment monitoring and control, and realtime and post-treatment analysis; and interstitial and endocavity ultrasound heating applicators. Hardware includes a 32-channel RF amplifier with independent power (0-25 W) and frequency (5-10 MHz) control for ultrasound power delivery and a 48-channel thermometry system compatible with 0.4 mm OD multi-sensor thermocouple probes. Software graphical user interfaces (GUI) are used to monitor and control both the amplifier and the thermometry system. The amplifier GUI controls, monitors, and records individual channel frequency and power values in real-time; the thermometry GUI monitors and records temperature and thermal dose values in real-time, as well as displaying and allowing dynamic control for temperature and thermal dose target thresholds. The thermometry GUI also incorporates registration of thermocouple positions relative to target anatomy and applicator transducers based on HDR planning tools (CT/MRI/US overlays) for improved treatment control and documentation. The interstitial (2.4 mm) and endocavity (6 mm) ultrasound hyperthermia applicators are composed of linear arrays of 1-4 tubular piezoceramic transducers - sectored at 90°, 180°, 270°, and 360° for single or dual directional heating patterns - that are compatible with plastic implant catheters. QA techniques specific to these catheter-based ultrasound applicators have been devised and implemented, and include rotational beam plots and dynamic force balance efficiency measurements, which are critical to establish applicator performance. A quality assurance test matrix has been devised and used to evaluate and characterize all components of this system prior to clinical implementation.
© (2009) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Titania Juang, Jeffery Wootton, I-Chow Hsu, and Chris Diederich "Treatment delivery platform for conformal catheter-based ultrasound hyperthermia", Proc. SPIE 7181, Energy-based Treatment of Tissue and Assessment V, 718109 (23 February 2009); https://doi.org/10.1117/12.808339
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Francium

Ultrasonography

Thermometry

Amplifiers

Control systems

Transducers

High dynamic range imaging

Back to Top