13 March 2009 Quantitative radiography enabled by slot collimation and a novel scatter correction technique on a large-area flat panel x-ray detector
Meghan L. Yue, Adam E. Boden, John M. Sabol
Author Affiliations +
Proceedings Volume 7258, Medical Imaging 2009: Physics of Medical Imaging; 725818 (2009) https://doi.org/10.1117/12.813552
Event: SPIE Medical Imaging, 2009, Lake Buena Vista (Orlando Area), Florida, United States
Abstract
In addition to causing loss of contrast and blurring in an image, scatter also makes quantitative measurements of xray attenuation impossible. Many devices, methods, and models have been developed to eliminate, estimate, and correct for the effects of scatter. Although these techniques can reduce the impact of scatter in a large-area image, no methods have proven to be practical and sufficient to enable quantitative analysis of image data in a routine clinical setting. This paper describes a method of scatter correction which uses moderate x-ray collimation in combination with a correction algorithm operating on data obtained from large-area flat panel detector images. The method involves acquiring slot collimated images of the object, and utilizing information from outside of the collimated region, in addition to a priori data, to estimate the scatter within the collimated region. This method requires no increase dose to the patient while providing high image quality and accurate estimates of the primary x-ray data. This scatter correction technique was validated through beam stop experiments and comparison of theoretically calculated and measured contrast of thin aluminum and polymethylmethacrelate objects. Measurements taken with various background material thicknesses, both with and without a grid, showed that the slot-scatter corrected contrast and the theoretical contrast were not significantly different given a 99% confidence interval. However, the uncorrected contrast was found to be significantly different from the corrected and theoretical contrasts. These findings indicate that this method of scatter correction can eliminate the effect of scatter on contrast and potentially enable quantitative x-ray imaging.
© (2009) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Meghan L. Yue, Adam E. Boden, and John M. Sabol "Quantitative radiography enabled by slot collimation and a novel scatter correction technique on a large-area flat panel x-ray detector", Proc. SPIE 7258, Medical Imaging 2009: Physics of Medical Imaging, 725818 (13 March 2009); https://doi.org/10.1117/12.813552
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Aluminum

Collimation

X-rays

X-ray imaging

Photons

Scatter measurement

Sensors

Back to Top