13 March 2009 Computed tomography quality indexes: evaluation experience
Sabina Strocchi, Cristina Vite, Raffaele Novario, Marco Cacciatori, Giovanna Frigerio, Leopoldo Conte
Author Affiliations +
Proceedings Volume 7258, Medical Imaging 2009: Physics of Medical Imaging; 72584T (2009) https://doi.org/10.1117/12.811501
Event: SPIE Medical Imaging, 2009, Lake Buena Vista (Orlando Area), Florida, United States
Abstract
Aim of this work was to identify proper figures of merit (FoM's) to quantitatively and objectively assess the whole acquisition process of a CT image and to evaluate which are more significant. Catphan® phantom images where acquired with a 64 slices computed tomography system, with head and abdomen protocols. Automatic exposure modulation system was on, with different settings. We defined three FoM's (Q, Q1 and Q2) including image quality parameters and acquisition modalities; two of them (Q and Q1) include also a radiation dose quantity, the third (Q2) does not. Then we drew from these the comparable FoM's (CNR, Q1 *, Q2), that do not have dose in their definitions, in order to investigate how they depend on perceived image quality. The FoM's were evaluated for each series. At the same time, expert observers evaluated the number of low contrast inserts seen in the phantom' images. The considered CNR, Q1*, Q2 FoM's are linearly related to the perceived image quality for both the acquisition protocols (head: r2=0.91;0.94;0.91; abdomen: r2=0.93;0.93;0.85). Q and Q1 values analysis shows that these FoM's can distinguish between different acquisition modalities (head or abdomen) with statistically significant difference (p<0.05). The studied FoM's can be usefully used to quantitatively and objectively assess the whole CT image acquisition process. Those FoM's including also radiation dose (Q, Q1) can be used to objectively quantify the equilibrium between image quality and radiation dose for a certain acquisition modality.
© (2009) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Sabina Strocchi, Cristina Vite, Raffaele Novario, Marco Cacciatori, Giovanna Frigerio, and Leopoldo Conte "Computed tomography quality indexes: evaluation experience", Proc. SPIE 7258, Medical Imaging 2009: Physics of Medical Imaging, 72584T (13 March 2009); https://doi.org/10.1117/12.811501
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Abdomen

Head

Image quality

Computed tomography

Image processing

Modulation transfer functions

Modulation

Back to Top