30 October 2009 An automatic method for measurement of vertebral bone density based on QCT without an external reference phantom
Kai Zhao, Xiao-guang Pan, Yu-yue Zou, Yan Kang
Author Affiliations +
Proceedings Volume 7497, MIPPR 2009: Medical Imaging, Parallel Processing of Images, and Optimization Techniques; 74972I (2009) https://doi.org/10.1117/12.830955
Event: Sixth International Symposium on Multispectral Image Processing and Pattern Recognition, 2009, Yichang, China
Abstract
Purpose: We developed an automatic method for measurement of vertebral bone density based on QCT with the use of internal references(muscle and subcutaneous fat) instead of traditional external phantom. Methods: The automatic multistep approach starts with segmentation of periosteal and endosteal surfaces of spine to define ellipse ROI in cancellous bone followed by segmentation of muscle and subcutaneous fat in the spine image and a subsequent calculation of bone mineral density in ellipse ROI and segmentation trabecular and cortical bone ROI using muscle and subcutaneous fat as internal references. The segmentation approach used a hybrid region-growing method which used local adaptive threshold and morphological operation. Results: We conducted with-phantom and without-phantom measurements by using 94 clinical cases. The doctor manually defined the ellipse ROI in the with-phantom measurement. As for the without-phantom measurement, we use our method to automatically gain the BMD. The Interaclass Correlation Coefficient (ICC) is 0.93. We removed the points whose muscle and fat values are 2 times deviated from the standard deviation. And the calibrated ICC value is 0.999. Conclusion: The without-phantom measurement method is not fit for the patients whose muscle and fat are seriously deviated from the average value. The without-phantom measurement method proposed in this paper can automatically measure the BMD of spine. By accurately segmenting cortical bone and trabecular bone, determining ROI and removing inappropriate data, it is proved that the BMD measurement result by this method is highly consistent with that by with-phantom method.
© (2009) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Kai Zhao, Xiao-guang Pan, Yu-yue Zou, and Yan Kang "An automatic method for measurement of vertebral bone density based on QCT without an external reference phantom", Proc. SPIE 7497, MIPPR 2009: Medical Imaging, Parallel Processing of Images, and Optimization Techniques, 74972I (30 October 2009); https://doi.org/10.1117/12.830955
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Image segmentation

Bone

Minerals

Calibration

Computed tomography

Spine

Statistical analysis

Back to Top