You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
5 October 2009FBG technology applied on container gantry overload warning
FBG (fiber Bragg grating) is used as a substitution of electrical strain gauge in port gantry overloading warning system.
A steel rope tension detecting device and FBG load cell were designed, and a rope force calibrating device was used. The force
analysis of tightened steel rope acting on FBG cell, and the process of the measuring data are introduced. The calibration shows that
the sensitivity of the system is around 90 pm/ton, and. it is of good performance, the accuracy and repeatability can be
0.73% in full scale, that is much less than 3%, which is the specification required.