Translator Disclaimer
Paper
5 October 2009 FBG technology applied on container gantry overload warning
Author Affiliations +
Proceedings Volume 7503, 20th International Conference on Optical Fibre Sensors; 75034R (2009) https://doi.org/10.1117/12.835507
Event: 20th International Conference on Optical Fibre Sensors, 2009, Edinburgh, United Kingdom
Abstract
FBG (fiber Bragg grating) is used as a substitution of electrical strain gauge in port gantry overloading warning system. A steel rope tension detecting device and FBG load cell were designed, and a rope force calibrating device was used. The force analysis of tightened steel rope acting on FBG cell, and the process of the measuring data are introduced. The calibration shows that the sensitivity of the system is around 90 pm/ton, and. it is of good performance, the accuracy and repeatability can be 0.73% in full scale, that is much less than 3%, which is the specification required.
© (2009) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Shunfan He, Weilai Li, Miao Gao, and Jianjun Pan "FBG technology applied on container gantry overload warning", Proc. SPIE 7503, 20th International Conference on Optical Fibre Sensors, 75034R (5 October 2009); https://doi.org/10.1117/12.835507
PROCEEDINGS
4 PAGES


SHARE
Advertisement
Advertisement
Back to Top