Paper
20 November 2009 Small roll angle measurement based on auto-collimation and moiré fringe
Xu-guang Bai, Sheng Cai, Ming Dai
Author Affiliations +
Abstract
A novel method for small roll angle measurement based on auto-collimation and moiré fringe is presented. A right-angle prism is used as an indicator of small roll angle around the optical axis, and a CCD is used to collect moiré fringes that are generated by scale grating image which is reflected by prism and index grating. Any small roll angle of the prism will change the include angle of the grating pair and meanwhile induce a change in the moiré fringe period. The relationship between roll angle and period of moiré fringes is established. The period data is obtained by image processing. The experimental result certifies that the principle of small angle measurement method based on auto-collimation and moiré fringe is correct and feasible. The measuring error is smaller than 0.2" within 7' range compared with 0.2" autocollimator.
© (2009) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Xu-guang Bai, Sheng Cai, and Ming Dai "Small roll angle measurement based on auto-collimation and moiré fringe", Proc. SPIE 7511, 2009 International Conference on Optical Instruments and Technology: Optoelectronic Measurement Technology and Systems, 75110Z (20 November 2009); https://doi.org/10.1117/12.837317
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Prisms

Image processing

Charge-coupled devices

Autocollimators

Collimators

Fringe analysis

Beam splitters

Back to Top