You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
22 March 2010Image reconstruction in cardiac interventions using a small flat-panel detector
C-arm CT is used in neurovascular interventions where a large flat panel detector is used to acquire cone-beam projection data. In this case, data truncation problems due to the limited detector size are mild. When the cone beam CT method is applied to cardiac interventions severe data truncation artifacts reduce the clinical
utility of the reconstructions. However, accurate reconstruction is still possible given a priori knowledge of the reconstruction values within a small region inside the FOV. Several groups have studied the case of the interior problem where data is truncated from all views. In this paper, we applied these new mathematical discoveries
to C-arm cardiac cone-beam CT to demonstrate that accurate image reconstruction may be achieved for cardiac
interventions. The method is applied to iteratively reconstruct the image volume such that it satisfies several
physical conditions. In this work, the algorithm is applied to data from in-vivo cardiac canine studies collected
using a clinical C-arm system. It is demonstrated that the algorithm converges well to the reconstruction values
of non-truncated data reconstructed using the FDK algorithm. Furthermore, proper convergence is achieved
by using only an estimate of the average value within a subregion as a priori information (i.e. the exact value
at each pixel in the a priori region need not be known). Two methods for obtaining a priori information are
compared.
The alert did not successfully save. Please try again later.
Pascal Thériault Lauzier, Jie Tang, Zhihua Qi, Guang-Hong Chen, "Image reconstruction in cardiac interventions using a small flat-panel detector," Proc. SPIE 7622, Medical Imaging 2010: Physics of Medical Imaging, 762228 (22 March 2010); https://doi.org/10.1117/12.844581