Paper
11 March 2010 Parallel image registration with a thin client interface
Ganesh Saiprasad, Yi-Jung Lo, William Plishker, Peng Lei, Tabassum Ahmad, Raj Shekhar
Author Affiliations +
Abstract
Despite its high significance, the clinical utilization of image registration remains limited because of its lengthy execution time and a lack of easy access. The focus of this work was twofold. First, we accelerated our course-to-fine, volume subdivision-based image registration algorithm by a novel parallel implementation that maintains the accuracy of our uniprocessor implementation. Second, we developed a thin-client computing model with a user-friendly interface to perform rigid and nonrigid image registration. Our novel parallel computing model uses the message passing interface model on a 32-core cluster. The results show that, compared with the uniprocessor implementation, the parallel implementation of our image registration algorithm is approximately 5 times faster for rigid image registration and approximately 9 times faster for nonrigid registration for the images used. To test the viability of such systems for clinical use, we developed a thin client in the form of a plug-in in OsiriX, a well-known open source PACS workstation and DICOM viewer, and used it for two applications. The first application registered the baseline and follow-up MR brain images, whose subtraction was used to track progression of multiple sclerosis. The second application registered pretreatment PET and intratreatment CT of radiofrequency ablation patients to demonstrate a new capability of multimodality imaging guidance. The registration acceleration coupled with the remote implementation using a thin client should ultimately increase accuracy, speed, and access of image registration-based interpretations in a number of diagnostic and interventional applications.
© (2010) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Ganesh Saiprasad, Yi-Jung Lo, William Plishker, Peng Lei, Tabassum Ahmad, and Raj Shekhar "Parallel image registration with a thin client interface", Proc. SPIE 7628, Medical Imaging 2010: Advanced PACS-based Imaging Informatics and Therapeutic Applications, 76280V (11 March 2010); https://doi.org/10.1117/12.844457
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Image registration

Computed tomography

Rigid registration

Image restoration

Positron emission tomography

Magnetic resonance imaging

Image fusion

Back to Top