You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
12 October 2010Bioaerosol standoff detection and correlation assessment with concentration and viability point sensors
A standoff bioaerosol sensor based on intensified range-gated spectrometric detection of Laser Induced Fluorescence
was used to spectrally characterize bioaerosol simulants during
in-chamber and open-air releases at Suffield, Canada, in
August 2008 from a standoff position. In total, 42 in-chamber Bacillus atrophaeus (formerly Bacillus subtilis var
globigii; BG) cloud and 27 open-air releases of either BG, Pantoea agglomerans (formerly Erwinia herbicola; EH),
MS2 and ovalbumin (OV) were generated. The clouds were refereed by different point sensors including Aerodynamic
Particle Sizer (APS) and slit or impingers samplers. The APS monitored the particle size distribution and concentration
and the samplers characterized the viable portion of the cloud. The extracted spectral signatures show robustness to
different degree. The correlation assessment showed good results in most cases where the LIF signal to noise ratio was
significant. The sensor 4σ sensitivity was evaluated to 1 300, 600, 100 and 30 ppl for BG, OV, MS2 and EH
respectively. Correlation results are presented by plotting the SINBAHD metric versus the corresponding particle
concentration, in which case, the obtained slope is proportional to the material fluorescence cross-section. The different
acquired signal is hence compared in terms of their fluorescence cross-section additionally to their spectral
characteristics.
Sylvie Buteau,Jean-Robert Simard,Susan Rowsell, andGilles Roy
"Bioaerosol standoff detection and correlation assessment with concentration and viability point sensors", Proc. SPIE 7838, Optics and Photonics for Counterterrorism and Crime Fighting VI and Optical Materials in Defence Systems Technology VII, 78380J (12 October 2010); https://doi.org/10.1117/12.864685
The alert did not successfully save. Please try again later.
Sylvie Buteau, Jean-Robert Simard, Susan Rowsell, Gilles Roy, "Bioaerosol standoff detection and correlation assessment with concentration and viability point sensors," Proc. SPIE 7838, Optics and Photonics for Counterterrorism and Crime Fighting VI and Optical Materials in Defence Systems Technology VII, 78380J (12 October 2010); https://doi.org/10.1117/12.864685