You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
16 February 2011High power distributed feedback and Fabry-Perot Al-free laser diodes at 780nm for rubidium pumping
Development of techniques such as atom optical pumping, for atomic clocks and matter-wave
interferometers (gyrometer, accelerometer, gravimeter and gradiometer), requires laser diodes with high power
and excellent spectral (narrow linewidth) and spatial qualities together with high reliability.
We have developed high power Fabry-Perot and distributed Feedback lasers diodes (DFB) emitting at
780nm corresponding to the D2 line of Rubidium.
We have realized a Fabry-Perot laser diode, without aluminium in the active region, with a cavity length
and a waveguide width of respectively 1mm and 4μm and an AR/HR coating on the facets. We obtain a low
threshold current around 40mA and a high slope efficiency of 1W/A at 20°C. We obtain a good beam quality M²
of 2 at 200mW. These lasers diodes are very interesting to be inserted in an external cavity.
For DFB lasers, we used a second order diffraction grating in a GaInP/GaAsP/GaInP waveguide. We
calculated the coupling coefficient KL of 1.5 for a length of 2mm, for a width of 4μm. These lasers show a low
threshold current (around 65mA) with a slope efficiency around 0.37W/A. We have obtained at 25°C, 145mA an
optical power of 25mW at the D2 line of Rubidium with a side mode suppression ratio around 44dB. By the selfheterodyne
method, we measured a low linewidth of our DFB laser at 780nm around 1.25MHz (lorentzian fit).
The alert did not successfully save. Please try again later.
C. Cayron, M. Tran, Y. Robert, M. Lecomte, M. Calligaro, O. Parillaud, M. Garcia, M. Krakowski, "High power distributed feedback and Fabry-Perot Al-free laser diodes at 780nm for rubidium pumping," Proc. SPIE 7953, Novel In-Plane Semiconductor Lasers X, 79530A (16 February 2011); https://doi.org/10.1117/12.873295