You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
15 April 2011Robust diagnostics for Bayesian compressive sensing with applications to structural health monitoring
In structural health monitoring (SHM) systems for civil structures, signal compression is often important to reduce the
cost of data transfer and storage because of the large volumes of data generated from the monitoring system.
Compressive sensing is a novel data compressing method whereby one does not measure the entire signal directly but
rather a set of related ("projected") measurements. The length of the required compressive-sensing measurements is
typically much smaller than the original signal, therefore increasing the efficiency of data transfer and storage. Recently,
a Bayesian formalism has also been employed for optimal compressive sensing, which adopts the ideas in the relevance
vector machine (RVM) as a decompression tool, such as the automatic relevance determination prior (ARD). Recently
publications illustrate the benefits of using the Bayesian compressive sensing (BCS) method. However, none of these
publications have investigated the robustness of the BCS method. We show that the usual RVM optimization algorithm
lacks robustness when the number of measurements is a lot less than the length of the signals because it can produce sub-optimal
signal representations; as a result, BCS is not robust when high compression efficiency is required. This induces
a tradeoff between efficiently compressing data and accurately decompressing it. Based on a study of the robustness of
the BCS method, diagnostic tools are proposed to investigate whether the compressed representation of the signal is
optimal. With reliable diagnostics, the performance of the BCS method can be monitored effectively. The numerical
results show that it is a powerful tool to examine the correctness of reconstruction results without knowing the original
signal.